Chelsio Communications Chelsio T5 Guia do Utilizador Página 172

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 171
Chapter X. FCoE PDU Offload Target
Chelsio T5/T4 Unified Wire For Linux Page 172
iv. Configure Chelsio interfaces (used for FCoE traffic) to come up with minimum MTU 2180
(recommended) during boot.
v. Configure FCoE target mode of operation (FCF or VN2VN) by editing
/etc/modprobe.d/chfcoe.conf
vi. By default the chfcoe service will be in disabled state. Enable it using the following
command:
[root@host]# chkconfig chfcoe on
To determine the run levels on which the service is enabled, run the following command:
[root@host]# chkconfig --list chfcoe
chfcoe 0:off 1:off 2:on 3:on 4:on 5:on 6:off
3.5. Verifying initiators connected to the target
Once connected to the target, initiators will be able to access the LUNs configured on the target.
Execute the following command to list the initiators which are connected to the target:
[root@host] # scstadmin list_session
Vista de página 171